UAT-600 Localizador cables subterráneos
UAT-600 Localizador cables subterráneos
UAT-600 Localizador cables subterráneos
UAT-600 Localizador cables subterráneos
UAT-600 Localizador cables subterráneos

UAT-600 Localizador cables subterráneos

SKU: UAT-620

Detecta cables subterráneos hasta 6 mtrs de profundidad. Diseñado para electricistas (CAT IV 600 V), los kits de localización se suministran listos para usar con un transmisor, receptor y cables de prueba.

Features

UAT-600-R Receiver

UAT-600-T Transmitter

SC-600 Signal Clamp (included with UAT-620, optional for UAT-610)

Measurement category

CAT IV 600 V

Operating voltage/current

0 to 600 V

0 to 600 V, 100 A max.

Operating frequency/tracing modes

Active tracing: 33 kHz and 8 kHz
Passive tracing: 50/60 Hz and Radio

Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz and 33 kHz
Clamp mode: 8 kHz and 33 kHz
De-Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz, 33 kHz, A-Lo/A-Hi
A-Frame: 8 kHz
Clamp mode: 8 kHz and 33 kHz

33 kHz and 8 kHz

Locating modes

Peak and Null

Depth measurement and accuracy

Up to 20 ft
4 in to 10 ft: pm; 3 %
10 ft to 20 ft: pm; 5 %

Display backlight

Automatic

Yes

Audio indication

Increasing closer to the signal

Fast beeps showing the better signal is applied

Transmitting mode power output

Max. 3 watts

Output voltage

Max. 50 V rms

Output current

Max. 250 mA rms, constant current in 5 steps

Signal voltage output (nominal)

23 V rms at 8 kHz
30 V rms at 33 kHz

Mains voltage measurement

0 V to 600 V, 50 Hz to 60 Hz
Resolution: 1 V
Accuracy: pm; 10%

Resistance measurement
(De-energized circuit)

0 ohm; to 999 k ohm;
Range: 0 ohm; to 999 ohm; (resolution: 5 ohm;)
Range: 1 k ohm; to 999 k ohm; (resolution: 1 k ohm;)
Accuracy: pm; 10%

Output hazardous voltage warning

≥ 30 V rms

Mains hazardous voltage warning

≥ 30 V rms

Sensitivity adjustment (gain control)

Yes

Sensitivity at 1 m (typical)

Power: 2 mA
Radio: 20 μA
8 kHz: 5 μA
33 kHz: 5 μA

Display

4.3 in, 320 x 240 BW outdoor LCD display with auto backlight

LCD display (LED backlight)
2.4 in x 1.3 in

Update rate

Instantaneous

Current (mA): 10 ms
Voltage (V): 15 ms
Resistance ( ohm;): 330 ms

Operating temperature and humidity

-4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH

Storage temperature and humidity

-40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH

Operating altitude

< 6561 ft (< 2000 m)

Pollution degree

2

Water and dust resistance

IP54

Drop proof

3.28 ft (1 m)

Power supply

(6) 1.5 V AA alkaline batteries

(8) 1.5 V D cell alkaline batteries

Auto power off

15 minutes idle

Battery life

Approx. 35 hours at 70 °F (21 °C) (Typical)

Approx. 16 hours at 70 °F (21 °C) (Typical)

Overload protection

600 V rms
Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm

Safety compliance

IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033

Size (H x W x L)

Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm)

IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-031, CSA/UL 61010-031 (test leads)

IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033

Weight

Approx. 4.2 lb (1.9 kg) (batteries installed)

Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm)

Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm)

 

 

 

 

 